8000IS X-Long Hose FAQ
How to install the direct feed?
The direct feed goes in the very bottom brass fitting on the left side of the unit (the middle valve directly above it must be closed at all times when using direct feed).
How to increase or decrease the steam?
Steam pressure is adjusted by the small black knob found on the top of the unit. Turn to the left to increase the steam volume and to the right to decrease.
How to drain unit ?
Remove plug from the end of drain so to attach drain hose, then proceed to open the drain valve and empty water into bucket. This should be done In the morning before work while unit is still cold.
What do I do when the low water light comes on?
Check that the water feed is on.
Does it come in 220V?
No it is only available in 120V.